TM 9-6115-668-13N O T ETo remove right hand shock absorber, control cabinet must be re-moved.To remove left hand shock absorber, battery set must be removed.1.2.3.4.Remove unit hood assembly (1, figure 5-52) as instructed in paragraph 4.14.Remove upper part of partition (4) as instructed in paragraph 5.47, steps 3 through 6.Remove air filter and piping (3) as instructed in paragraph 5.27.Remove control cabinet (11) as instructed in paragraph 4.43 and battery set (2) as instructed inparagraph 4.74.5:Install lifting device to lifting lugs (62) and (70).6.Remove two bolts (60), two serrated lock washers (59), and two washers (58).7.Lift synchronous generator (61).8.Remove two bolts (56) and two serrated washers (55).9.Remove shock absorber plate (54)10. Remove two bolts (53), two serrated lock washers (52), and two washers (51).11. Remove shock absorber (50).12. Remove two bolts (46), two serrated lock washers (47), two washers (48), and mounting plate (49)from shock absorber (50).N O T EIt is not necessary to install suitablespacing material or remove liftingdevice if shock absorber is to be replaced immediately.13. Install suitable spacing material.CAUTIONUse Loctite 243 on bolts.Tighten wrench to torque values in table (item G.1, appendix G)5-221
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business