TM 9-6115-668-13
INSTALLATION
NOTE
l
Installation procedure for miniature relay K103 (6), K104 (7), K111
(9) is the same as for miniature relay K105 (8), described below.
l
Before inserting flat connector (16) with cable (17) into relay socket
(12), bend backsnap-in hooks (18).
1.
Install cable (17) with flat connector (16) in relay socket (12):
a. Noting correct labeling and position of cables to relay socket (12), insert cables (17) with flat
connectors (16) from below into relay sockets (12) until they stop.
b. Pull on cable (17) to check that snap-in hook (18) has snapped into relay socket (12).
2.
Install relay socket (12) of miniature relay K105 (8):
a. Insert relay socket (12) into mounting grooves of adjacent relay sockets and push downward.
b. Push the four relay sockets (12) toward mounting bar (11).
c. Install screws (15), serrated lock washers (14), and washers (13) into clips (10) on mounting bar
(11).
3.
Install miniature relay K105 (8):
a. Insert miniature relay K105 (8) into relay sockets (12) and push in all the way.
4.
Stow prop (5) and close front panel (4).
5.
Close flap (2).