TM 9-6115-668-13Figure 5-36 Time Relay K110INSTALLATIONNOTEInstallation procedure for all relays is the same as for time relay K106, de-scribed below.1.Insert time relay K106 (27) into top of mounting bar (41) and push in at the bottom.2.Noting correct labeling and position, install cables (31, 34) to lower terminals (32, 35) andtighten screws (33, 36).3.Noting correct labeling and position. Install cables (23, 25) to upper terminals (22, 26) andtighten screws (21, 24).4. Stow prop (5) and close front panel (4).5. Close flap (2).5-151