TM 9-6115-668-13
Figure 5-35 Time Relay K108
4.
Set time relay K110 (20) to switching time of 180 seconds:
a. On front of time relay K 110 (20), use TIME DIP switches (1) to set a time window of 3 minutes
as shown in figure 5-36.
b. On front of time relay K 110 (20), use rotary knob (3) to set a multiplication factor of 1.
5-149