TM 9-6115-668-13
5.20 TIME RELAY MAINTENANCE.
This task covers:
a. Removal
b. Test
c. Installation
d. Adjust
INITIAL SETUP
Tools
Equipment Conditions
General Mechanics Tool Kit
(item 2, appendix B)
Automotive Fuel and Electrical System Repair, Tool Kit
(item 3, appendix B)
Watch, stop
(item 5, appendix B)
Materials/Parts
Reference
Generator Set 150 kW shut down,
paragraph 2.5.2
Cable ties
(item 10, appendix E)
WARNING
Disconnect the negative battery cable first and then the positive bat-
tery terminal cables. Failure to observe this warning could result in se-
vere personal injury or death.
C A U T I O N
Tag all cables prior to removal to ensure correct connection of the cables
during installation.
REMOVAL
1.
Open flap (2, figure 5-37) on unit hood assembly (1).
2.
Open front panel (4) of control cabinet assembly (3) and secure with prop (5).
N O T E
Removal procedure for all time relays is the same as for time relay
K106, described below.
3.
Record labeling and position of cables (23, 25) to upper terminals (22, 26) of time relay K106 (27),
loosen screws (21, 24) and remove cables (23, 25).
4.
Record labeling and position of cables (31, 34) to lower terminals (32, 35) of time relay K106 (27),
loosen screws (33, 36) and remove cables (31, 34).
5.
Use a screwdriver to push locking element (30) on time relay K106 (27) in direction of arrow, tilt
time relay K106 (27) upward, and remove from mounting bar (41).
5 - 1 4 5