TM 9-6115-668-134.76EHG REGULATOR N7 MAINTENANCE.This task covers:a. Removalb. InstallationGeneral Mechanic’s Tool Kit(item 2, appendix B)Automotive Fuel and Electrical System Repair, Tool Kit(Rem 3, appendix B)ReferenceGenerator Set 150 kW shutdown,paragraph 2.5.2Hylomar(item 15, appendix E)Disconnect the negative battery cable first and then the positive bat-tery terminal cables. Failure to observe this warning could result insevere personel injury or death.CAUTIONTag all cables prior to removal to ensure correct connection of thecables during installation.1.Open flap (3, figure 4-60).2.Remove two screws (54) and two washers (55) from plug connector 2J7 (53).3.Remove plug connector 2J7 (53) with seal (56) from EHG regulator N7 (50).4.Remove two nuts (59), two washers (57), serrated lock washers (58), two screws (51), twowashers (52), and EHG regulator N7 (50) from bracket (60).1.Install EHG regulator N7 (50) on bracket (60) using two screws (51), two washers (52), two wash-ers (57), two serrated lock washers (56), and two nuts (59). Tighten nuts (59).Apply Hylomar to both sides of seal (56) of plug connector 2J7 (53).2.Install plug connector 2J7 (53) and rubber seal (56) on EHG regulator N7 (50).3.Install screws (51), washers (52) Washers (57), serrated lock washers (58), and nuts (59). Tightennuts (59).4. Close flap (3).4-185