TM 9-6115-668-134.74 BATTERY SET MAINTENANCE.This task covers:a. Removalb. Testc.InstallationToolsEquipment ConditionsGeneral Mechanic’s Tool KitReference(item 2, appendix B)Generator Set 150 kW shutAutomotive Fuel and Electrical System Repair, Tool Kitdown,(item 3, appendix B)paragraph 2.5.2WARNINGBefore removing the batteries, disconnect first the negative terminaland then the positive terminal of the battery set. Failure to observethiswarning could result in severe personal injury or death.CAUTIONTag ail cables prior to removal to ensure correct connection of the cablesduring installation.1.2.3.4.5.6.7.8.9.Open flap (3, figure 4-60) on unit hood assembly (1).Remove terminal cover cap (25).Loosen nut (27) on terminal connector of negative terminal and remove terminal connector with bat-tery cable (26).Remove terminal cover cap (28).Loosen nut (30) on terminal connector of positive terminal and remove terminal connector with bat-tery cable (29).Loosen nuts (42) on clamping device (41) and swing clamping device (41) aside.Remove upper part (37) of battery set holder from batteries (38, 39).Remove terminal cover caps (31, 32).Loosen nut (35) at terminal connector of positive terminal of battery (39) and nut (34) at terminalconnector of negative terminal of battery (38) and remove battery cable (33).10. Grasp batteries (38, 39) individually by lifting handles (36) and lift out of lower part (40) of batteryset holder.4-181