TM 9-6115-668-13
1.
Measure no load voltage Uo:
a. Switch off load resistors of lead battery tester.
b. Apply test probes with correct polarity to terminals (+ and -) of battery (38, 39).
c. Read off no load voltage Uo value displayed on lead battery tester.
NOTE
l
if no load voltage Uo < 12.5 V, charge battery with charger vi J3
slave receptacle 24 V Connector.
l
if the battery gets very hot during charging, It is defective and must
be replaced.
l
When no load voltage Uo > 12.5 V, measure load voltage UB.
2. Measure load voltage UB:
a. On the lead battery tester, activate the number of load resistors required for the particular type
of battery.
b. Apply test probes with correct polarity to terminals (+ and -) of battery (38, 39).
c. Read off load voltage UB value displayed on lead battery tester.
NOTE
l
if load voltage UB > 10.0 V, battery is at least 40% charged, and its
high current load capability is sufficient for starting.
l
if load voltage UB < 10.0 V, charge battery with charger via J3 slave
receptacle 24 Connector.
1.
Using lifting handles (36), insert batteries (38, 39) individually into lower part (40) of battery set
holder.
2.
Install terminal connector of battery cable (33) on negative terminal of battery (38) and tighten nut
(34)
3.
Install terminal connector of battery cable (33) on positive terminal of battery (39) and tighten nut
(35).
4.
Install terminal cover caps (31, 32).
5.
Place upper part (37) of battery set holder on batteries (38, 39).
6.
Swing clamping device (41) into place, hook into upper part (37) of battery set holder, and tighten
screws (42).
4-182