TM 9-6115-668-134.75 BATTERY CHARGING ALTERNATOR REGULATOR N6 MAINTENANCE.This task covers:a. Removalb. InstallationEquipment ConditionsGeneral Mechanic’s Tool Kit(item 2, appendix B)Automotive Fuel and Electrical System Repair, Tool Kit(item 3, appendix B)ReferenceGenerator Set 150 kW shutdown,paragraph 2.5.2WARNINGDisconnect the negative battery cable first and then the positive bat-tery terminal cables. Failure to observe this warning could result In se-vere personal injury or death.CAUTIONTag ail cables prior to removal to ensure correct connection of the cablesduring installation.1.Open flap (3, figure 4-60) on unit hood assembly (1).2.Remove cable with plug connector 2J5 (45) from battery charging alternator regulator N6 (46).3.Remove two nuts (49), two serrated lock washers (48), two washers (47), two screws (43), and twowashers (44) and remove battery charging alternator generator regulator N6 (46) from bracket (60).1.Install battery charging alternator generator regulator N6 (46) on bracket (60), using two screws(43) two washers (44), two washers (47), two serrated lock washers (48), and two nuts (49).Tighten nuts (49).2.Install plug connector 2J5 (45) on battery charging alternator generator regulator N6 (46).3. Close flap (3).4-184