TM 9-6115-668-134.73 SHUNT R11 MAINTENANCE.This task covers:a. Removalb. installationGeneral Mechanic’s Tool KitReference(Item 2, appendix B)Generator Set 150 kW shutAutomotive Fuel and Electrical System Repair, Tool Kitdown,(item 3, appendix B)paragraph 2.5.2Disconnect the negative battery cable first and then the positive bat-tery terminal cables. Failure to observe this warning could result insevere personal Injury or death.CAUTIONTag all cables prior to removal to ensure correct connection of thecables during installation.1. Open flap (2, figure 4-60) on unit hood assembly (1).2.Remove screw (11), spring washer (10), washer (9), and cable 02 (8).3.Remove screw (7), washer (6), and cable 05 (5).4.Remove screw (15), spring washer (16), washer (17), and cable 2 (18).5.Remove screw (12), washer (13), and cable 06 (14).6.Remove nuts (24), serrated lock washers (23) and washers (22), and screws (19) and removeshunt R11 (4) from engine block together with washer (20),), and mounting plate (21).1.Install shunt R11 (4) and mounting plate (21) on engine block using screws (19) and washers (20).2.Install washers (22), serrated lock washers (23), and nuts (24). Tighten nuts (24).3.Install cable 6 (14) with screw (12) and washer (13).4.Install cable 2 (18) with screw (15), spring lock washer (16), and washer (17).5.Install cable 5 (5) with screw (7) and washer (6).6.Install cable 02 (8) with screw (11), spring lock washer (10), and washer (9).7. Close flap (2).4-180