TM 9-6115-668-13
4.20 TWIST GRIP AND LOCK MAINTENANCE.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Equipment Conditions
General Mechanics Tool Kit
(item 2, appendix B)
Automotive Fuel and Electrical System Repair, Tool Kit
(item 3, appendix B)
Reference
Generator Set 150 kW shut
down, paragraph 2.5.2
REMOVAL
NOTE
This procedure will be used to remove twist grips and locks from all
flaps.
1.
Open flap (19, figure 4-28).
2.
Remove four screws (12) while retaining self-locking nut (18).
3.
Remove twist grip (13) from flap (19).
4.
Remove lock (16) on flap (19) by removing two screws (17) from flap (19).
5.
Loosen set screw (15) and remove pin (14) from lock (16).
INSTALLATION
1.
Install twist grip (13) on flap (19) using four screws (12) and four nuts (18).
2.
Install pin (14) in lock (16) and secure by tightening set screws (15).
3.
Install lock (16) on flap (19) with two screws (17).
4.
Close flap (19).
4-55