TM 5-6115-584-12NAVFAC P-8-622-12TO-35C2-3-456-1TM-05682C-12Table 3-3. Troubleshooting (Cont)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION7. GENERATOR SUPPLIES NO VOLTAGE TO LOAD.Step 1. Check main circuit breaker for ON position on ac output control box.Place circuit breaker in ON position. If breaker will not stay on, perform the followingactions:Make certain load leads are attached to the correct load terminals.Make certain connections are clean and tight.Verify load is not excessive to generator capability and does not have an internal short.Notify higher level maintenance.8. GENERATOR SUPPLIES IMPROPER (UNDER OR OVER) VOLTAGE FREQUENCY TO LOAD.Step 1. Check reconnection switch on ac output control box.Make certain switch position matches load.Disconnect load before switching.Step 2. Check load terminal board (paragraph 3-17).Make certain load leads are attached to the correct load terminals. Make certainconnections are clean and tight.Step 3. Check engine speed.Adjust engine speed by turning speed control assembly until frequency meter oncontrol panel indicates 60 Hz with load on Generator Set.If engine speed cannot be brought up so that Generator operates at 60 Hz, checkexternal governor linkage for binding and check steps under ENGINE STARTSBUT DOES NOT RUN SMOOTHLY.If engine speed cannot be brought down so that Generator operates at 60 Hz, checkexternal governor linkage for binding or notify higher level maintenance(paragraph 3-21).3-11. BATTERY ASSEMBLY.a. Inspect (see figure 3-2). On generators equipped withacoustic suppression kit (ASK), remove batteries access door forInspection.(1) Inspect battery cable terminal connectors (2), (10) and(11) for corrosion, deterioration, or physical damage. Inspectbattery terminal covers (16) for proper installation and physicalcondition. Replace if cracked, split or torn.(2) Inspect cables (l), (3), and (4) for breaks, damage andSection V. OPERATOR MAINTENANCE PROCEDURES(3) Inspect battery top frames (5), bottom frame (12),and tray (13) for corrosion or physical damage. Check tosee that frame is held securely in place and that allattaching hardware, nut (7), washer, (8), screw (14), washer(15), and bolt (9), is securely in place. Check that frame is freeof electrolyte.(4) Inspect battery (6) for leaks or cracks. Check topof battery and battery caps for cleanliness. Check bat-tery electrolyte (liquid) level. Level should bedeteriorated insulation.3 -8C h a n g e 7
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business