load equals a 100% meter reading for maximum ratedload. A 1.0 power factor load equals a 80% meterreading for maximum rated load.i. During operating of the Generator Set observethe following.(1) Check % rated current meter.(2) Check fuel level gauge periodically.(3) Oil pressure gauge located on engine shouldindicate 20 psi minimum.(4) Check running time meter periodically inorder to perform preventive maintenance check andTM 5-6115-584-12NAVFAC P-8-622-12T O - 3 5 C 2 - 3 - 4 5 6 - 1TM-05682C-12(5) Battery indicator should indicate yellow whilebattery is charging, green when battery is fullycharged.(6) AC voltmeter should indicate 120V., 208V. or240V. depending on load connection.(7) Frequency meter should indicate 60 Hz (atfull rated load).j. During operation, inspect for leaks, paying par-ticular attention to engine fuel and oil lines and con-services at proper intervals.nections.Figure 2-4. Load Terminal and Reconnection Configuration2-5