E - HEATER CONTROL PANEL
STEP 4. PRESS HEATER CIRCUIT BREAKER AND PRESS THE PRESS-TO-TEST INDICATOR, INDICATOR
LAMP SHALL LIGHT.
STEP 5. SET ON - OFF SWITCH TO ON. INDICATOR LAMP SHALL LIGHT WHEN HEATER GOES INTO RUN
CYCLE (APPROXIMATELY THREE MINUTES). OPERATE HEATER FOR 50 MINUTES OR UNTIL CYCLE
OPERATION OCCURS AS INDICATED BY EXTINGUISHING OF INDICATOR LAMP.
NOTE
IF INDICATOR LAMP DOES NOT LIGHT IN APPROXIMATELY FOUR MINUTES,
SET ON-OFF SWITCH TO OFF. WAIT THREE MINUTES BEFORE ATTEMPTING
TO RESTART HEATER.
STOPPING
STEP 1. SET ON-OFF SWITCH TO OFF. INDICATOR LAMP SHALL REMAIN ILLUMINATED UNTIL HEATER
COMPLETE PURGE CYCLE (APPROXIMATELY 4-1/2 MINUTES).
STEP 2. AFTER INDICATOR LAMP EXTINGUISHES, REENERGIZE BREAKER.
STEP 3. CLOSE BOTH COOLANT SHUTOFF VALVES (B AND C).
STEP 4. TURN MANUAL HEATER FUEL VALVE TO OFF.
STEP 5. PLACE COOLANT SELECTOR VALVE (D) HANDLE (IN 9-O'CLOCK POSITION) POINTING DIRECTLY
AWAY FROM FUEL BURNING HEATER.
ME 6115-545-12/2-11(2) C1
Figure 2-11.
Fuel Burning Winterization Kit Operating Instructions (Sheet 2 of 2)
Change 1