4.69 CONNECTOR J9 MAINTENANCE.
This task covers:
a. Removal
b. Installation
Tools
Equipment Conditions
General Mechanics Tool Kit
Reference
(item 2, appendix B)
Generator Set 150 kW shut down,
Automotive Fuel and Electrical System Repair, Tool Kit
paragraph 2.5.2
(item 3, appendix B)
Removal Tool
(item 10, appendix B)
Installation Tool
(item 11, appendix B)
Materials/Parts
Cable ties
(item 10, appendix E)
WARNING
Disconnect the negative battery cable first and then the positive bat-
tery terminal cables. Failure to observe this warning could result in se-
vere personal injury or death.
CAUTION
Tag all cables prior to removal to ensure correct connection of the cables
during installation.
1.
Remove unit hood assembly (1, figure 4-58) as instructed in paragraph 4.14.
2.
Open front panel (4) of control cabinet assembly (3) and secure with prop (5).
3.
Remove eighteen screws (6), eighteen serrated lock washers (7), and eighteen washers (8) from
panel (9).
4.
Lower control cabinet connection panel (9) and prop.
5.
Remove two nuts (42) and cover (43) from spacer (41).
6.
Remove four nuts (11), serrated four lock washers (12), four washers (13).
7.
Remove four screws (18) and four washer (17) from control cabinet connection panel (9).
8.
Remove connector J9 (15), protective cap (16), and seal (14).
9.
Remove protective cap (16) from connector J9 (15).
10. Remove contact bushings:
4-171