TM 9-6115-662-13&P1.2.3.4.5.6.7.8.Remove 21 screws (1, figure 5-15), lock washers (2), and flat washers (3) that secure the switch boxcover (4) to the switch box assembly. Discard lock washers.CAUTIONThe control panel connector P3 is connected to connector J4. Movement of the switch boxcover is limited. To prevent damage to control panel wiring harness, use cautionremoving switch box cover. Failure to observe this caution can result in equipmentdamage.Carefully position switch box cover (4) in front of the switch box assembly.Disconnect P3 (5) horn J4 (6) and set switch box cover (4) out of the way.Remove and retain the switch box cover (4).Remove four screws (7) and one terminal shield (8) from the contactor (9).Remove six nuts (10) and washers (11)Tag and remove six leads from contactor (9).Remove eight terminal screws (12) and washers (13). Tag and remove wiring harnesses fromcontactor (9).Remove four nuts (14), screws (15), flat washers (16), and contactor (9).INSTALLATION1.2.3.4.5.6.7.8.Position new contactor (9) over mounting holes in bracket (17).Install a flat washer (16) on each screw (15).Install four screws (15), flat washers (16), and nuts (14) to secure contactor (9).Remove four screws (7) and terminal shield (8) from the new contactor (9).Connect the wiring harness and six electrical leads and install washers (13 and 11), screws (12), andnuts (10).Install terminal shield (8) on new contactor (9) and secure with screws (7).Connect P3 (5) to J4 (6) and position switch box cover (4) over the switch box assembly.Install flat washers (3), lock washers (2), and screws (1) that secure switch box cover (4).5-30