TM 9-6115-662-13&P
5-8 CONTROL PANEL ASSEMBLY MAINTENANCE.
This task covers:
Removal
b. Installation
Repair
a.
b.
INITIAL SETUP
Tools
Equipment Conditions
Tool Kit, General Mechanics
(item 1, appendix B)
Reference
Both generator sets shut down, para 2-5.3.1.
Trailer support devices are
Materials/Parts
lowered, paragraph 2-3.2.1.
Washers, Lock
REMOVAL
1.
2.
3.
4.
Release clamping catch (6, figure 5-13) and open the control panel access cover (5).
Remove 8 screws (9), flat washers (11), and lock washers (10) that secure control panel assembly (12).
Discard lock washers.
Disconnect P3 (7) from J4 (8).
Remove the control panel assembly (12).
REPAIR
NOTE
Spare lamps must be tied to ground for electromagnetic interference (EMI) protection.
Refer to appendix G and repair or manufacture wiring harness W-20.
INSTALLATION
1.
2.
3.
4.
Connect P3 (7, figure 5-13) to J4 (8).
Position new control panel assembly on mounting plate and align mounting holes.
Install new lock washers (10), flat washers (11), and screws (9) that secure control panel assembly (12)
to switch box assembly (4).
Close the control panel access cover (5) and secure with clamping catch (6).
5-23