TM 9-6115-659-13&P
Table 2-2. Operator Preventive Maintenance Checks and Services
Location
Item
Interval
Procedure
Not Fully Mission
No.
Item to
Capable if:
Check/Service
42
During
CONTROLS AND Observe the following indicators and
Frequency or AC
INDICATORS
ensure they are operating properly.
voltmeter
inoperative.
COOLANT TEMP.
170-200°F (77-930C)
OIL PRESSURE
25-60 psi (172-414 -
kPa)
FREQUENCY
60 Hz
VOLTAGE
120-240 VAC
43
During
GROUND ROD
Inspect ground rod and cable for loose
Cable is missing or
CABLE AND
connections, breaks, damage and
damaged.
CONNECTIONS
corrosion.
44
After
HOUSING
a. Check doors, panels, hinges, and
Cannot secure
clamping catches for damaged, loose, or
doors.
corroded items.
b. Inspect air intake and exhaust grills for
debris.
45
After
IDENTIFICATION Check to ensure identification plates are
PLATES
secure.
46
After
SKID BASE
Inspect skid base for cracks and corrosion.
Skid base is
cracked or shows
signs of structural
damage.
47
After
ENGINE
Check for loose, damaged, or missing
ASSEMBLY
hardware.
48
After
FUEL SYSTEM
Inspect fuel system for leaks, and
Any fuel leaks, and
damaged, loose, or missing hardware.
damaged, loose, or
missing parts.
49
After
FUEL FILTER/
a. Inspect fuel filter/water separator for
Any fuel leaks.
WATER
leaks, cracks, damage, proper
SEPARATOR
mounting, or missing parts.
b. Drain water from fuel filter/water
separator.
WARNING
The fuels used in this generator set are highly explosive. Do not smoke or use open flame
when performing maintenance. Flames and explosion can occur resulting in severe
personal injury or death.
2-26 Change 2