TM 9-6115-659-13&P
Table 2-2. Operator Preventive Maintenance Checks and Services
Location
Item
Interval
Procedure
Not Fully Mission
No.
Item to
Capable if:
Check/Service
38
During
ENGINE
Check for loose, damaged, or missing parts
ASSEMBLY
39
During
FUEL SYSTEM
Inspect for leaks, damaged, loose, or
Any fuel leaks,
missing parts.
damaged or loose
parts.
40
During
LUBRICATION
Inspect for leaks, damaged, loose, or
Class III leaks,
SYSTEM
missing parts.
and damaged, or
loose parts.
41
During
COOLING FAN
Listen for unusual noise in fan area.
WARNING
With any access door open, the noise level of this generator set when operating could
cause hearing damage. Hearing protection must be worn when working near the
generator set while running.
WARNING
The fuels used in this generator set are highly explosive. Do not smoke or use open
flame when performing maintenance. Flames and explosion can occur resulting in
severe personal injury or death.
WARNING
Exercise extreme caution when performing "During" checks inside engine compartment.
Avoid contact with moving or hot engine parts. Failure to observe this WARNING can
result in severe personal injury or death.
WARNING
High voltage is produced when this generator set is in operation. Improper operation
could result in severe personal injury or death.
Change 2 2-25