TM 9-6115-659-13&PTable 2-2. Operator Preventive Maintenance Checks and ServicesLocationItemIntervalProcedureNot Fully MissionNo.Item to Capable if:Check/ServiceWARNINGBattery acid can cause burns to unprotected skin.WARNINGBatteries give off a flammable gas. Do not smoke or use open flame when performingmaintenance. Flames and explosion could result in severe personal injury or death.30BeforeBATTERYInspect cables and connectors forCables are loose,CABLEScorrosion, damage, loose, or missing parts.damaged, ormissing.WARNINGHigh voltage is produced when this generator set is in operation. Personal injury or deathdue to electrocution could result.31BeforeOUTPUT BOXa. Check for loose or damaged wiring orLoose or damagedASSEMBLYcables.wiring or cables.b. Check output terminals for damage orDamaged ormissing hardware.missing hardware.32BeforeCONTROLS ANDa. Check all indicators and controls forIndicators orINDICATORSdamage or missing parts.controls damagedor missing.b. Press PUSH TEST RESET LAMPSbutton (46) on fault indicator. Alllights must light.Change 2 2-23