TM 9-6115-659-13&P
Table 2-2. Operator Preventive Maintenance Checks and Services
Location
Item
Interval
Procedure
Not Fully Mission
No.
Item to
Capable if:
Check/Service
2
7Before
OVERFLOW
Check overflow bottle (41) for leaks or
Class III leaks.
BOTTLE
missing parts. Check coolant level.
WARNING
Exhaust discharge contains deadly gases. DO NOT operate generator set in enclosed
areas unless exhaust discharge is properly vented outside. Severe personal injury or
death due to carbon monoxide poisoning could result.
28
Before
EXHAUST
Check muffler (42) for leaks and exhaust
Muffler or exhaust
SYSTEM
system for corrosion, damaged, or missing
system damaged or
parts.
leaking.
29
Before
AIR CLEANER
a. Inspect air cleaner assembly (43) and
Loose or missing
ASSEMBLY
piping (44) for loose or damaged
parts.
connections.
b. Inspect restriction indicator (45) for
Clogged element is
clogged element. If indicator shows red,
indicated or piping
notify next higher level of maintenance.
and connections
are loose.
2-22 Change 2