TM 9-6115-659-13&P
Table 2-2. Operator Preventive Maintenance Checks and Services
Location
Item
Interval
Procedure
Not Fully Mission
No.
Item to
Capable if:
Check/Service
13
Before
SWITCH BOX
a. Check for loose or missing mounting
Two or more
ASSEMBLY
hardware.
mounting bolts
(POWER PLANTS
missing.
ONLY)
b. Check for damaged indicator lights.
Indicator lights are
damaged.
c. Check hinges and clamping catches.
d. Check for loose or damaged switches.
Switches loose or
damaged.
e. Check output terminals and connectors
Output terminals
for damaged or missing hardware.
or connectors will
not properly secure
load cables.
14
Before
HYDRAULIC
Check for leakage of brake fluid from
Brake system
any
BRAKES
master cylinder
(24), hydraulic brake lines
leak.
and fittings (25), and backing plates (26).
Change 2 2-17