TM 9-6115-604-34NAVFAC P-8-633-34Table 1-5. System Capacities and Detailed Data on Components (Continued)AC ELECTRICAL POWER GENERATION AND CONTROL SYSTEM (CONTINUED)Output Voltage:Manufacturer:Part Number:FSCM:Voltage RegulatorDrawing Number:Sensing Terminals (El, E2 and E3):Voltage:Burden:Input Power (Terminals 3 and 4):Voltage:VA (maximum continuous):Output Field Power(Terminals F+ and F-):Maximum Continuous:Maximum Forcing:DC Field Resistance (minimum):Frequency:Voltage Regulation:Response Time:EMI (ElectromagneticInterference):Voltage Adjust Range:Ambient Operating Temperature:Storage Temperature:Temperature Coefficient:Power Dissipation:Vibration:With operating voltage selector in 2400 volt connectionposition:A. At 60 Hz: 2160 to 2640 voltsB. At 50 Hz: 1980 to 2420 voltsWith operating voltage selector in2400/4160 volt connection position:A. At 60 Hz: 3750 to 4575 voltsB. At 50 Hz: 3420 to 4180 voltsMarathon ElectricSS5113523815180-7546120/203/240/416/430/600 V acLess than 10 VA per line240 V ac1680125Vdcat7A180 V dc at 1OA18 ohms50/60 HzLess than 1.4%Less than 17 millisecondsMIL-STD-461, Class III B,conducted or radiated10% of nominal voltage-67 to 158° F (-55 to +70C)-85 to 212 F (-65 to +10C)Less than ±1.2% for 122 F (50C)temperature change (after 20 minuteswarm-up)Less than 60 wattsWithstands 1.3 G's from 5 to 26 Hz, 0.036 inchdisplacement from 26 to 52 Hz and 5 G's from52 to 260 Hz1-23
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business