TM 9-6115-604-34NAVFAC P-8-633-34Table 1-5. System Capacities and Detailed Data on Components (Continued)AC ELECTRICAL POWER GENERATION AND CONTROL SYSTEM (CONTINUED)Humidity Conditions:Manufacturer:Part Number:FSCM:Overcurrent RelayDrawing Number:Type:Frequency:Current Taps:Pickup Range:Operating Temperature:Storage Temperature:Humidity Conditions:Manufacturer:Part Number:FSCM:Type BF RelayDrawing Number:Rating:Contact Material:Contacts:Terminals:Number of Poles:Coil Data:Pickup Time:Dropout Time:Operating Temperature:Storage Temperature:Humidity Conditions:AC Rating:DC Rating:Manufacturer:Part Number:FSCM:Relay SocketDrawing Number:Voltage Breakdown:Contact Rating:Insulation:To 100%General Electric121AV52D1A0349780-73953 phase50/60 Hz4, 5, 6, 7, 8, 10, and 12 amperes4 to 12 amperes-25 to +125F (-31 to 51C)-65 to +155F (53 to 68C)To 100%Brown Boveri Electric223T13943613780-7894120 V ac, 110 V ac, 10 amperes continuous, 50/60 Hz;amperes make 60; amperes break 6; volt amperesmake 7200; volt amperes break 720Silver alloy2 normally open, 2 normally closedCaptive clamp211 to 18 milliseconds ac11 to 18 milliseconds ac-25° to +125F (-31 to 51C)-65 to +155F (-53 to 68C)To 100%NEMA A300NEMA N300Westinghouse ElectricBF22F8994669-6583500 V dc10 amperesPer MIL-M-14, Type GD1 -301-28