5-19. TEST AND REPLACE SPECIAL RELAY ASSEMBLY TO REMOTE FUNCTIONS BOX
ASSEMBLY WIRING HARNESS (cont)
b.
c.
REPAIR
Use a multimeter and test for
open circuit between pins and
pin-to-connector.
When opens or shorts occur,
repair wiring harness.
REPAIR WIRING HARNESS.
a.
Use standard shop procedures
when repairing the wiring
harness.
b.
If not repairable, fabricate
(see Appendix G).
INSTALLATION
INSTALL WIRING HARNESS.
a.
Connect P29A (1) connector to
the remote functions box
assembly (2) at J29A (3).
b.
Install connectors P29 (4) and
PA (5) to the special relay
box (6) at J29 (7) and JA (8).
NOTE
FOLLOW ON MAINTENANCE: Connect
Negative Battery Cable (Para.
4-10).
5-28