TM5-6115-634-14&PNAVFAC P-8-647-14&PT0-35C2-3-445-14TM-6115-14&P/15-21.TEST AND REPLACE SS2P TO CONVENIENCE RECEPTACLE WIRING HARNESS (cont)TESTTEST CONVENIENCE WIRING HARNESS.a.Use a multimeter and test forcontinuity between pins, alsotest for open circuit betweenpins.b.When open or short occurs,repair wiring harness.REPAIRREPAIR WIRING HARNESS.a.Use standard shop procedureswhen repairing the wiringharness.b.If not repairable, fabricate(see Appendix G).INSTALLATIONINSTALL CONVENIENCE WIRING HARNESS.a.Connect wire XN12B to thereceptacle and wire XN9B tothe circuit breaker.b.Connect connector SS2P to con-nector SS2R.NOTEFOLLOW ON MAINTENANCE: InstallConvenience Receptacle and CircuitBreaker (TM5-6115-464-12, Para.3-124.)5-33