TM5-6115-593-34
NAVFAC P-8-631-34
TO-35C2-3-463-2
Flashing Circuit (FCI)
Flasher
DOD Drawing Number.. ............ 76-11396 24V DC,
No. 313 lamp
Terminal
DOD Drawing Number.. ............ 76-11241
Synchroscope Meter
DOD Drawing Number..7 .......... 6-11219
Voltage ............. ....................... 120V AC, 50/60 Hz
Accuracy .................................. 2 degrees
Pull-in frequency ....................... 48 Hz
Dropout frequency... ................. 47 Hz
i. Parallel Cable Assemblies.
DOD Drawing Number.. ............ 76-11320 and
76-11321
76-11320
1200 ft (365 m)
76-11253 cable
76-11321
1200 ft (365 m)
76-11253 cable
j. Housing Kit.
Actuator
DOD Drawing Number.. ............ 76-11475
Voltage ............. ....................... 24V DC
Load ................ ........................ 250 pounds (113.5
kilograms)
Speed ............... ....................... 1.0 in/sec
(25.4 mm/sec)
Current .............. ...................... 7 amps
26.5V DC Relay
DOD Drawing Number.. ............ 76-11444
Coil resistance ..... .................... 300 ohms
.............................................. +10 percent
Contact type ........ .................... DPDT with arc
chamfer
Contact rating ..... ..................... .10 amp resistance
at 26.5V DC/
115V AC 400
Hz with
enclosure
grounded
Max pull-in volts........................ 18V DC
Min holding volts....................... .10V DC
Min dropout volt .... ................... 1V DC
Operating time at... ................... 15MS max
26.5V DC
Release time at ........................ 15MS max
26.5V DC
NOTE
Throughout this technical manual MEP-029A is
referrd to as code A and MEP-029B is referred to as
code B.
1-8.
INSTRUCTION
PLATES.
Refer
to
the
Operator/Crew and Organizational .Maintenance manual
for location of instruction plates in the generator set.
1-9. TORQUE DATA. Table 1-1 lists components that
require special torques.
1-10. SCHEMATICS AND WIRING DIAGRAMS. FO-1
through FO-16 of the Operator/Crew and Organizational
Maintenance manual are the schematic and wiring
diagrams for the generator set and auxiliary equipment.
1-11. SERIAL NUMBER EFFECTIVITY.
Refer to TM5-6115-593-24P, Usable on Code data.
Table 1-1. Special Torque Data
TORQUE VALUE
COMPONENTS
FT/LBS
JOULES
GENERATOR
Generator mount to skid base screws
202
274
Flexible coupling to flywheel screws
112
152
ENGINE
Front trunnion mounting bolts
202
274
Bell housing mounting bolts
296
401
Main bearing capscrew
Tighten to
200 min/210 max
271min/285 max
Advance to
410 min/420 max
555 min/570 max
Loosen
all
Tighten to
200 min/210 max
271 min/285 max
Advance
420 min/460 max
570 min/624 max
* Applicable to Generator Set serial numbers FZ00001-FZ00064 only
* Cap screw should be coated with 30 weight oil
1-5