TM5-6115-593-34
NAVFAC P-8-631-34
TO-35C2-3-463-2
Annunciator Control Assembly
DOD Drawing Number. ............. 76-11272
Diodes (20) ........... ................... JANIN4383
1 amp, 200 volt
Relays (13) ............................... M5757/23-003
10 amp, DPDT,
MIL-R-5757
Diodes, Silicone
DOD Drawing Number. ............. 76-11244
Five diodes ........... ................... 400 prv, 3 amps
Resistor
Type .................. ................... RWR74S3920RFR,
39,000 ohms,
+5 percent,
MIL-R-22
Resistor Assembly TB107
DOD Drawing Number.. ............ 70-1131
Two resistors ............................ 7.5 ohms, +5
percent
Resistors
R4 (TD2) .................................. 820 ohms, 25
watts
+5 percent
R1 (TD2) .................................. 2 k, 1 watt,
+5 percent
R2 (TD2)................................... 2.7 megohms,
25 watts,
+5 percent
R3 (TD2)................................... 390 k, 0.25 watt,
+5 percent
Capacitors
C1 (TD2) .................................. 10 microfarads,
25 volts,
+5 per-cent
C2 (TD2)................................... 47 microfarads,
50 volts,
+5 per-cent
Flashing Circuit (FC1)
Flasher
DOD Drawing Number... ........... 76-11396
24V DC, No.
313 lamp
Terminal
DOD Drawing Number... ........... 76-11241
Digital Clock
DOD Drawing Number... ........... 76-11221
Input ............... ......................... 120V AC, 50/60 Hz
Features .............. .................... 50 to 60 Hz
select; fast
and slow set,
and hold
Synchroscope Meter
DOD Drawing Number.. ............ .76-11219
Voltage ........................................... 120V AC, 50/60 Hz
Accuracy ......................................... .2 degrees
Pull-in frequency ............................. 48 Hz
Dropout frequency........................... 47 Hz
Underfrequency Relay
DOD Drawing Number .............. 77-11002
Input .................. ...................... 1 20V AC 50 or
60 Hz
Trip Characteristic..................... .50 or 60 Hz - 3%
(adjustable)
Overfrequency Relay
DOD Drawing Number... ........... 77-11001
Input ................. ....................... 120V AC 50
or 60 Hz
Trip Characteristic..................... 50 or 60 Hz - 3%
(adjustable)
Over/Under Voltage Relay
DOD Drawing Number .............. 77-11003
Input ................ ..................... 120V AC 50
or 60 Hz
Trip Characteristic.. .................. 50 or 60 Hz - 3%
120V AC +10%
(adjustable)
Synchronizer Relay
DOD Drawing Number .............. 77-11006
Input ............. ........................... 120V AC 50 or
60 Hz
Output ...................................... Will allow breaker
closing when
buss and
generator
voltages are
matched to
within
+.5%
frequency,
+10% voltage.
e. Fuel Transfer Pump.
Solenoid Valve
DOD Drawing Number... ........... 69-787-1
24V DC, 2-way
normally closed
Rated ....................................... 25 psi
f. Generator and Reconnection
Assembly.
Limit Switch
DOD Drawing Number.. ............ 76-11295
Type ................. ....................... .Roller Plunger
Contacts ......... ......................... DPST - 1 NO - 1
NC
600 volts max
6 amps at 600V
AC, 15 amps at
-30V AC
Current Transformer
DOD Drawing Number... ........... 76-11259
Ratio ........................................ 1155/1 - 12.5VA
Max current through ... .................... .1.5 amp
winding
Continuous at 68°F ......................... 1.5 amp
(20 C)
Insulation class ............................... .600V AC
1-3