TM5-6115-593-34
NAVFAC P-8-631-34
TO-35C2-3-463-2
components of the generator set are provided in the
applicable maintenance paragraphs of this manual.
1-7. TABULATED DATA. This paragraph contains all
maintenance data pertinent to intermediate (field) (direct
and general support) and depot maintenance personnel.
The generator set has identification and instructional
plates located throughout the set. The information
pertaining
to
these
plates
is
contained
in
the
Operator/Crew and Organizational Maintenance manual.
a. Generator Set.
Manufacturer .................................. Fermont Division,
Dynamics Cor-
poration of
America
DOD Drawing Number... ................. 76-029
Model ............................................. MEP-029B
Mode .............................................. 50/60 Hertz
3 phase, 4 wire
Class .............................................. Utility
b. External Power Box Assembly.
Starter Motor Contactor
DOD Drawing Number .............. 76-11254
Contact Rating
Volt .................................... hp
200 ............... ..................... 10
230 ................ .................... 15
380-575 ........... .................. 25
Overload trip ...... ............................ 35.5 to 38.2 amps
Nominal operating........................... .120V AC, 50/60 Hz
Required operating.......................... 50 Hz nominal from
ranges
110 to 123V AC
and from 47.5
to 52.5 Hz
60 Hz nominal from
114 to 144V AC
and from 57.5
to 62.5 Hz
c. AC-DC Control Box Assembly.
Battery Charger
DOD Drawing Number.. ............ 76-11207
AC Input ............. ..................... 120V AC, 50/60 Hz
DC Output ................................ 24V DC, 20 amps
Fuse protection ..... ................... AC input and DC
output
Diodes, zener (measured with
associated resistor)
CR1 (TD1) ........ ....................... .6.8 volts
CR4 (TD3) ......... ...................... 15 volts
Resistors
R116 ........................................ 5 ohms, 14 watts,
+5 percent
R4 (TD1) .................................. 820 ohms, 25 watts
+5 percent
R1
(TD1) 2 k, 1 watt,
+5 percent
R2 (TD1) .................................. 2.7 megohms, 25
watts,
+5 percent
R1 (TD3) .................................. 2 k, 1 watt,
+5 percent
R2 (TD3) .................................. 2 k, 1 watt,
+5 percent
R4 (TD3) .................................. 2 k, 0.25 watt,
+5 percent
R7 (TD3) .................................. 20 k, 0.25 watt,
+5 percent
R6 (TD3)................................... 200 ohms, 1 watt,
+5 percent
R5 (TD3) .................................. 68 k, 0.25 watt,
+5 percent
R3 (TD3) .................................. .6 k, 0.25 watt,
+5 percent
Capacitors
C1 (TD1) .................................. 10 microfarads,
25 volts,
+5 per-cent
C2 (TD1) ........... ............................. 47 microfarads,
50 volts,
+5 per-cent
C1 (TD3) ........... ............................. 300 microfarads,
30 volts,
±5 per-cent
Governor Controller
DOD Drawing Number... ........... 76-11208
Inputs ....................................... 90 to 240V AC,
3 phase load
sensing
24V DC supply,
10 watts con-
sumption
900 to 2700
rpm speed
range
Output ............................................ Voltage to actu-
ator 0 to 8V DC
Operating range .............................. 40 to 160°F (-40
to 71°C)
Voltage Regulator
DOD Drawing Number .............. 76-11209
Power input............................... 120V AC, 50/60 Hz
840VA
Output rating............................. 62.5V DC, 7 amps
mas
continuous;
90V DC, 10
amps
1 minute
forcing
Sensing..................................... 208V AC, 3 phase,
50/60 Hz
Voltage regulation..................... +1/2 percent
Response time ......................... T6 milliseconds
d. Control Cubicle Assembly.
Alarm Horn
DOD Drawing Number... ........... 76-11225
Input .................. ...................... 24V DC
Output ...................................... 370 cycles per
second, audible
1-2