(2) Timing Method 1. This is a means for calcu-lating the correct button thickness before the pump isinstalled. It requires the port closing dimensions andbutton thickness from the pump being replaced. Sub-stitute the dimensions for those in the formula belowand calculate the new button thickness. Determine thebutton code letter from table 7-1.Example Formula:TM5-6115-585-34NAVFAC P-8-262-12TO-35C2-3-455-2TM-05684C-34NOTEAlways use button thickness closest to thisdimension.Install the correct button in pump (figure 7-33) andinstall pump following the instructions under injec-tion pump installation above.(3) Timing Method 2. Flowing the Pump.Port closing dimension of old pump(a) Install a Number 12 or M timing button in(removed from engine) . . . . . . . . . . 1.093injection pump and install pump on engine, followinginstructions under injection pump installation above.Button thickness of old pump . . . . . . . +0. 1191.212Port closing dimension of new pump . . . . -1.089When removing tappets which contain timingButton thickness of new pump . . . . . . .0.123buttons, do not allow the portion of the injec-tion pump which has the face gear to be liftedUse button Mfrom its position.Figure 7-43. Delivery Valve7-39