MAGNETIC AMPLIFIER BIAS TEST.TURN Rll, R12, R14, R15, R16,R18 FULL CW.CONNECT GOVERNOR CONTROLUNIT TO TEST EQUIPMENT ASSHOWN.ADJUST Rll AND Rl2 FOR BAL-ANCED READING OF 450 MA ONM2 AND M3.TURN R12 FULL CW. M2 AND M3SHALL READ 0-300 MA, AND BEBALANCED WITHIN 50 MA.TURN R12 FULL CCW. M2 ANDM3 SHALL READ 600-1000 MA,AND BE BALANCED WITHIN 50 MA.READJUST Ml AND R12 FOR BAL-ANCED READING OF 450 MA ONM2 AND M3 AND LOCK Rll ANDRl2 FOR REMAINDER OF TEST.TEST EQUIPMENTREFDESQUANTITYDESCRIPTIONM2, M32MILLIAMMETER, DC, 0-1000 MAV11DC POWER SOURCE1AC POWER SOURCEME 6115-545-34/7-7Figure 7-7. Electric Governor Control Unit, Magnetic Amplifier Bias Test (400 Hz)7-11
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business