REFDESRaRb, RCM2, M3FREQUENCY SENSING CHECK (HIGH ANDLOW FREQUENCY)CONNECT GOVERNOR CONTROL UNIT TOTEST EQUIPMENT AS SHOWNTURN Ra SO THE RESISTANCE BETWEENP1-M AND P1-T IS 250 OHMS.REDUCE THE FREQUENCY OF THE AP-PLIED 120 ± 2 VOLT SUPPLY UNTIL M2AND M3 BALANCE.THE FREQUENCY SHALL BE 375-380 Hz.TURN Ra SO THE RESISTANCE BETWEENP1-M AND P1-N IS 250 OHMS.INCREASE THE FREQUENCY OF THEAPPLIED 120 ± 2 VOLT SUPPLY UNTILM2 AND M3 BALANCE.THE FREQUENCY SHALL BE 420-425 Hz.TEST EQUIPMENTQUANTITYDESCRIPTION1POTENTIOMETER, 10 TURN, 500 OHMS, 5 WATT2RESISTOR, FIXED, 250 OHMS, 5 WATT2MILLIAMMETER, DC, 0-1000 MA1DC POWER SOURCE1AC POWER SOURCEME 6115-545-34/7-8Figure 7-8.Electric Governor Control Unit, Frequency Sensing Check (400 Hz)7-12
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business