P-8-627-34
T O 35C2-3-442-2
TM-07464A-35 TM 5-6115-457-34
order of index numbers assigned. Pay par-
CLEANING.
3-3.
ticular attention to the following:
a. Clean electrical components with a
cloth moistened with an approved cleaning
solvent, and dry thoroughly.
NOTE
WARNING
Wiring harness interconnecting dia-
Cleaning Solvents are flammable and
gram is contained in Operator and
moderately toxic to skin, eyes and
Organizational Maintenance Manual
respiratory tract. Eye and skin
protection required. Good general
a. Install convenience receptacle assem-
ventilation is normally adequate.
bly in rear housing and secure with six
screws and washers. Connect harness to
b. Clean metal components with an ap-
assembly.
proved cleaning solvent, and dry thorough-
b. Install fault locater panel in rear
ly.
housing and secure with four screws. Con-
nect harness to locator panel.
3-4.
INSPECTION.
c. Install control cubicle, as specified
d. Refer to Operator and Organizational
b. Inspect terminal lugs for security
Maintenance Manual and perform the follow-
and condition.
ing:
c. Inspect air intake panel screen for
1. Install radiator and shutter
holes and tears.
assembly.
d. Inspect components for dents,
c r a c k s , distortion.
f rent housing and receptacle mounting panel.
e. Inspect threads for damage.
3. If necessary, install kit control
f. I n s p e c t o r damage paint.
panels.
REPAIR.
3-5.
4. Install manual speed control.
a . Straighten dented and distorted
5. Connect parallel receptacle har-
sheet metal parts using suitable tools.
ness in rear housing.
b. Remove damaged paint. Blend in
6. Install DC control circuit breaker.
edges, prime, and paint damaged areas.
REASSEMBLY AND INSTALLATION.
3-6.
7. Install housing panels and doors.
8. Connect negative battery cable.
and install housing frame in the reverse
Change 8
3-4