TM 5-6115-400-12
Figure 3-9. Moisture collector manifold drain.
Section V. TROUBLESHOOTING
3-15. General
3-16. Troubleshooting Table
This section provides information useful in diagnosing
Malfunctions which may occur are listed in table 3-3.
unsatisfactory operation or failure of the generator set or
Each malfunction stated is followed by a list of probable
its components.
causes of the trouble.
The corrective action
recommended is described opposite the probable cause.
Table 3-3. Troubleshooting
Malfunction
Probable cause
Corrective action
1.
Engine will not turn
a.
Batteries weak.
a. Recharge or replace batteries
b. Repair or replace starter or
switch inoperative.
3-56).
c.
Engine is locked or seized.
c. Refer to higher echeon
2.
Engine hard to start
a.
Batteries weak.
a. Recharge or replace batteries
b.
Incorrect grade of fuel.
b. Drain fuel system. Fill the
tank with the specified fuel. Refer
3-12