TM 9-6115-668-13
5.28
SUBCURRENT FILTER ASSEMBLY MAINTENANCE.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Equipment Conditions
General Mechanics Tool Kit
(item 2, appendix B)
Automotive Fuel and Electrical System Repair, Tool Kit
(item 3, appendix B)
Materials/Parts
Cable ties
(item 10, appendix E)
Reference
Generator Set 150 kW shut
down
paragraph 2.5.2
1. Open flap (2, figure 5-41) on unit hood assembly (1).
Place a container under sub-fuel filter and collect oil as It emerges.
Completely drain subfuel filter and oil lines.
After removal, plug oil lines and tie up.
2.
Remove cables ties (26,29) from oil lines.
3.
Remove drain plug (10) and sealing ring (11) from subcurrent filter (5).
NOTE
Use new sealing ring.
4. Allow oil to drain out. and screw in drain plug (10) and sealing ring (11).
5.
Remove hollow screw (9),, oil line (7), and sealing rings (6, 6) from s¤t filter (5).
6.
Remove hollow screw (15), remove oil line (13), and sealing rings (12, 14) from subcurrent filter (5).
7.
Remove nuts (19), serrated lock washers (16) and washers (17).
6.
Remove screws (3), washers (4), and subcurrent filter (5) from bracket (16).
5-168