TM 9-6115-668-134.83 SILENCER ASSEMBLY, RIGHT SIDE MAINTENANCE.This task covers:a. Removalb. InstallationToolsEquipmentConditionsGeneral Mechanic’s Tool KitReference(item 2, appendix B)Generator Set 150 kW shutAutomotive Fuel and Electrical System Repair, Tool Kitdown,(item 3, appendix B)paragraph 2.5.2Materials/PartsHeat shielding tape (Hesiflex, white, 020.05.0003)(item 18, appendix E)WARNINGDisconnect the negative battery cable first and then the positive bat-tery terminal cables. Failure to observe this warning could result Insevere personal Injury or death.1.Remove unit hood assembly (1, figure 4-64) as instructed in paragraph 4.14.WARNINGWhen Generator Set 150 kW is supported, secure to prevent tipping.When working on silencer assembly, allow to cool first or wear gloves.To work on underside of base frame, support Generator Set 150 kW on stands.Provide at least 19.7 Inches (50 cm) of working space.2.Raise Generator Set 150 kW:a. Attach cables to lifting device and ring bolts (3) on base frame (2) and lift Generator Set 150 kWonto supports.3.Remove silencer assembly, right side.WARNINGThis task requires three persons: some parts weigh up to 88.2 pounds (40 kg).4-205