TM 9-6115-668-13
4.82
SILENCER ASSEMBLY, LEFT SIDE MAINTENANCE.
This task covers:
a. Removal
b. Installation
General Mechanics Tool Kit
Reference
(item 2, appendix B)
Generator Set 150 kW shut
Automotive Fuel and Electrical System Repair, Tool Kit
down,
(item 3, appendix B)
paragraph 2.5.2
Heat shielding tape (Hesiflex, white, 020.05.003)
(item 18, appendix E)
Three
Disconnect the negative battery cable first and then the positive bat-
tery terminal cables. Failure to observe this warning could result in se-
vere personal injury or death.
1.
Remove unit hood assembly (1, figure 4-63) as instructed in paragraph 4.14.
When Generator Set 150 kW is supported, secure to prevent tip-
ping.
When working on silencer assembly, allow to cool first or wear
gloves.
To work on underside of base frame, support Generator Set 150 kW
on stands.
Provide at least 19.7 inches (50 cm) of working space.
2.
Raise Generator Set 150 kW:
a.
Attach cables to lifting device and ring bolts (3) on base frame (2) and lift Generator Set 150 kW
onto supports.
3.
Remove silencer assembly, left side.
4-200