TM 9-6115-668-134.80 LOWER FUEL LEVEL SWITCH MAINTENANCE.This task covers:a. Removalb. InstallationToolsEquipmentConditionsGeneral Mechanic’s Tool KitReference(item 2, appendix B)Generator Set 150 kW shutAutomotive Fuel and Electrical System Repair, Tool Kitdown,(item 3, appendix B)paragraph 2.5.2Crimping tool(item 14, appendix B)Materials/PartsHylomar(item 15, appendix E)Fish wire, 60 inches (1,5 m) in lengthAdhesive tape(item 17, appendix E)Cable ties(item 10, appendix E)WARNINGDisconnect the negative battery cable first and then the positive bat-tery terminal cables. Failure to observe this warning could result insevere personal injury or death.WARNINGThe fuel in this Generator Set 150 KW is highly explosive. Do notsmoke or use open flame when performing maintenance. Fire and ex-plosion could occur, resulting in severe personal injury or death.1.Remove unit hood assembly (I, figure 4-62) as instructed in paragraph 4.14.WARNINGAvoid open flame or sparks during this procedure.4-195