TM 9-6115-668-134.60 LIGHT INDICATOR ASSEMBLY MAINTENANCE.This task covers:a. Removalb. InstallationToolsEquipmentConditionsGeneral Mechanic’s Tool KitReference(item 2, appendix B)Generator Set 150 kW shutAutomotive Fuel and Electrical System Repair, Tool Kitdown,(item 3, appendix B)paragraph 2.5.2Materials/PartsCable ties(item 10, appendix E)Disconnect the negative battery cable first and then the positive bat-tery terminal cables. Failure to observe this warning could result in se-vere personal injury or death.Tag all cables prior to removal to ensure correct connection of thecables during installation.1.Open flap (2, figure 4-52) on unit hood assembly (1).2.Open front panel (4) of control cabinet assembly (3) and secure with prop (5).Removal procedure for transformer T14 (6) is the same as for trans-former T15 (7) described below.3.Record labeling and position of cables (8) on upper terminals (9) of transformer T15 (7), loosenscrews (10), and remove cables,4.Record labeling and position of cables (12) on lower terminals (13) of transformer T15 (7), loosenscrews (11) , and remove cables.5.Use a screwdriver to push locking element (14) on Transformer T15 (7) in direction of arrow, tilttransformer T15 (7) upward and remove from mounting bar (16).4 - 1 4 4
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business