TM 9-6115-668-13
CAUTION
Assure ground strap is free and will not snag when removing hood.
9.
Secure hoisting device to eye bolts (31 to 34), lift unit hood (1) off base frame assembly (12) and
place on a flat surface.
INSTALLATION
Note the sequence of attaching hardware for installation to ensure
proper grounding. Failure to observe this warning could cause se-
vere personal Injury or death.
Ensure fuel hose is secure and properly stowed inside the hood prior
to Installation to prevent damage to the hose.
1.
Align rubber sealing strip (20) in U-profile on bottom plate.
2.
Coat rubber seal (21) on partition wall with assembly lubricant.
3.
Insure rubber fuel fill hose (38) and two metal band hose clamps (37) have been installed on fuel
tank inlet.
4.
Attach hoisting device to eye bolts (31 to 34), lift up unit hood (1), and position above base frame
assembly (12) so the U-profile on the inside of the unit hood is located above rubber seal (21) on
partition wall.
NOTE
The rubber seal (21) and lnsulating mat on the partition wall must
slide into the U-profile.
5.
Lower unit hood (1) until it rests evenly on rubber sealing strip (20) in the U-profile on the base
frame assembly (12), and on the partition wall rubber seal (21). insure fuel filler neck slides down
into rubber fill hose (38).
6.
Detach hoisting device from eyebolts (31 to 34).
7.
Swing up eye screws (14) with nuts (18). washers (16), and plates (15), and set plates (15) in re-
tainers (13).
8.
Tighten nuts (17) and secure with lock nuts (18).
9.
Install grounding strap (8) on stud (11) with nut (6), serrated lock washer (7), and washers (9,10).
10. Place case for connection panel (30). with seal, in unit hood (1) and attach to unit hood with ten
bolts (22), ten serrated lock washers (23), and ten washers (24).
11. Align attachment rail (28) and rubber cover (19) on unit hood (1) and secure with six bolts (25), six
serrated lock washers (26), and six washers (27).
12. Open flap (36), tighten the two metal band hose clamps (37).
4-46
Change 1