TM 9-6115-668-13
4.13 UNIT HOOD FLAP GROUND STRAP MAINTENANCE.
This task covers:
a. Removal
INITIAL SETUP
Tools
b. installation
Equipment Conditions
General Mechanics Tool Kit
(item 2, appendix B)
Automotive Fuel and Electrical System Repair, Tool Kit
(item 3, appendix B)
Reference
Generator Set 150 kW shut
down, paragraph 2.5.2
REMOVAL
WARNING
1.
2.
3.
l
Note the removal sequence of attaching hardware to ensure proper
installation sequence.
l
Failure to observe this warning could result in severe personal In-
jury or death.
N O T E
This procedure is the same for flaps (3), (4) and (5).
Open flap (2, figure 4-24).
Remove nut (6), serrated lock washer (7), washers (8, 9), and grounding strap (10) from screw (11)
on unit hood assembly (1).
Remove nut (12), serrated lock washer (13), washers (14, 15), and grounding strap (10) from screw
(16) on flap (2).
INSTALLATION
1.
Install washers (14, 15), serrated lock washer (13), and grounding strap (10) on screw (16), and
install nut (12) onto screw (16) on flap (2).
2.
Install washers (8, 9), serrated lock washer (7) and grounding strap (10) on screw (11), and install
nut (6) on screw (11) on unit hood assembly (1).
3. Close flap (2).
4 - 4 3