TM 9-9115-668-13
4.14
UNIT HOOD ASSEMBLY MAINTENANCE.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Equipment Conditions
General Mechanics Tool Kit
(item 2, appendix B)
Automotive Fuel and Electrical System Repair, Tool Kit
(item 3, appendix B)
Sling/Hoisting Device, Universal
(item 7, appendix B)
Reference
Generator Set 150 kW shut
down,
paragraph 2.5.2
Materials/Parts
Personnel Required
Lubricant
(item 6, appendix E)
Two - Three
REMOVAL
1
Remove six bolts (25, figure 4-25) six lock washers (26) and six washers (27) from connection
panel case (30).
2.
3.
Remove attachment rail (28) and rubber cover (29).
Remove ten bolts (22) ten serrated lock washers (23) and ten washers (24) from connection panel
case (30).
4.
5.
Remove connection panel case (30) with seal and protection profile out of unit hood (1).
Using a 19 mm wrench, loosen six lock nuts (18) six eye bolts (14) six nuts (17) six washers (16),
and six plates (15).
6.
Lift six plates (15) out of retainers (13) and fold down six eye bolts (14) six nuts (17) six washers
(16) and six plates (15).
7.
Remove nut (6) serrated lock washer (7) washers (9, 10), and ground strap (8) from stud (11) on
base frame (12). Install washer (9, 10), serrated lock washer (7) and nut (6) on stud (11) to prevent
loss of hardware.
8.
Open flap (36) and loosen two band clamps (37) on rubber fuel fill hose (38).
This procedure requires a minimum of two personnel
Stay clear of the suspended load. Failure to observe this warning
could result In severe personal injury or death.
Change 1 4-45