TM 9-6115-658-13&P
2-30
2-6.2 AN/MJQ-43 Identification/Transportation Data Plate. Refer to Figure 2-10. This plate is
located on front of roadside fender.
Figure 2-10. AN/MJQ-43 Identification/Transportation Data Plate.
2-7
PREPARATION FOR MOVEMENT.
2-7.1 Shut Down Power Plant. If power plant is operating, stop generator set as follows:
2-7.1.1 Power Plant. Refer to paragraph 2-5.3.3.
2-7.2 Disconnect Load Cables.
Make sure generator sets are shut down before connecting load cables. Failure
to observe this warning can cause severe personal injury or death.
a. For Power Plant configuration where load cables are connected to switch box load terminals,
perform the following:
(1) Release both clamping catches (1, Figure 2-11) and raise load terminal cover (2).
(2) Using load terminal box wrench, loosen load terminal nuts.
(3) Disconnect load cables (3) from switch box load terminals.
(4) Store load cables with equipment that was being supplied with electric power.
WARNING