TM 9-6115-658-13&P
5-9
Table 5-1.
Relay
Board Harness W11 Wire List
WIRE LIST
TERMINATION
TERMINATION
WIRE
NO.
FROM
ITEM
NO.
TO
TERMINAL
ITEM
NO.
WIRE
ITEM
NO.
1
K3-2
TB1-1
54
34
2
K3-3
TB1-6
54
34
3
K3-4
TB1-5
54
34
4
K3-5
TB1-3
54
34
5
K3-6
TB1-4
54
34
6
K3-7
TB1-2
54
34
7
K5-2
TB1-1
54
34
8
K5-3
TB1-8
54
34
9
K5-4
TB1-10
54
34
10
K5-5
TB1-17
54
34
11
K5-6
TB1-6
54
34
12
E-7
E-6
-
34
13
K4-2
TB1-14
54
34
14
K4-3
TB1-9
54
34
15
K4-4
TB1-5
54
34
16
K4-5
TB1-3
54
34
17
K4-6
TB1-7
54
34
18
K4-7
TB1-15
54
34
19
R1-1
TB1-17
54
34
20
K6-3
TB1-12
54
34
21
K6-4
TB1-11
54
34
22
K6-5
TB1-16
54
34
23
K6-6
TB1-13
54
34
24
K6-7
TB1-15
54
34
25
R1-2
E6
-
34
26
R2-2
E3
-
34
27
E5
TB1-1
54
34
28
E4
TB1-2
54
34
29
R2-1
TB1-16
54
34
30
E2
TB1-15
54
34
31
E1
E4
-
34
32
K5-7
TB1-2
54
34
33
E1
TB1-14
54
34
34
E8
TB1-18
54
34
35
K6-2
TB1-14
54
34
36
E9
E3
-
34
NOTE
Wire being checked must be disconnected at one location to isolate wire for
continuity
check.
3. If any wire fails continuity check, repair or replace relay board harness.
4. If all wires pass continuity check, install