TM 9-6115-658-13&P 5-14TEST1. Repeat removal step above. 2. Refer to Figure 5-7 and check continuity of relay coil between pins X1 and X2. Figure 5-7. Relay Schematic. Dangerous voltage exists on live circuits. Always observe precautions and never work alone. Failure to observe this warning could result in severe personal injury or death. 3. Attach 24 VDC power source across pins X1 and X2 of relay and check continuity of relay contacts before and after relay is energized as listed in Table 5-2. Table 5-2. Relay Operation RELAY STATUS CONTINUITY BETWEEN PINS NO CONTINUITY BETWEEN PINS Power NOT Applied A2 and A3 B2 and B3 A1 and A2 B1 and B2 Power Applied A1 and A2 B1 and B2 A2 and A3 B2 and B3 4. If all multimeter indications are correct, perform installation procedures. 5. If any multimeter indication is not as listed in Table 5-2 perform installation with new relay. INSTALLATIONInstall relay (3, Figure 5-6) in relay socket (4) and secure with two washers (2) and screws (1). WARNING