ARMY TM 9-6115-604-12NAVY NAVFC P-8-633-12Table 2-1. Engine Control Panel C, Controls and InstrumentsFigure 2-1, 15PRELUBE SYS switch S5When set to ON, prelube pump B3 andOFF (down)LUBE OIL PRESSURE gage Ml areenergized When set to off, LUBE OILPRESSURE gage Is connected to thegenerator set run circuit.Figure 2-1, 16MASTER SWITCH S9When set to START, the starter motorsRUNwill crank and the engine will startWhen set to STOP, engine fuel supplyis cut off and the engine stops. Whenreleased, this spring-loaded switchmoves to the RUN positionFigure 2-1, 17EMERGENCY LIGHTINGWhen set to ON, generator set emer-ONCB, CB2gency lights will illuminate if set is notoperating and utility power Is not avail-able.FIGUREANDINDEX NO.CONTROL ORINSTRUMENTFUNCTIONNORMALREADING/SETTING ATRATED LOAD2-4