TM-6115-634-14&PNAVFAC P-8-647-14&PT0-35C2-3-445-14TM-6115-14&P/15-23. MAINTENANCE OF CURRENT TRANSFORMER ASSEMBLIES (cont)(3) Replace transformer iftest steps c. (1) or (2)failed.INSTALLATION1.INSTALL TRANSFORMER ASSEMBLIES.a.b.c.d.e.f.g.5-40Install two mounting brackets(21), if removed, and securewith four screws (19) and flatwashers (20).Install cross-current compen-sation transformer (18) andsecure with two screws (16),lockwashers (17), and nuts(15).Install instrumentation trans-former assembly (14), andsecure with six screws (12) andflat washer (13).Install mounting brackets (11),if removed, and secure withfour screws (9) and flatwashers (10).Install current boost trans-former (8) and secure withfour screws (7), lockwashers(6), and nuts (5).Route generator leads throughtransformer windows whileobserving polarity as notedduring removal. See trans-former wiring table. Connectthe leads to voltage reconnectionboard.Remove tags. Retiewire bundles through thecoils.Connect electrical leads totransformer assemblies.Remove tags.