TM5-6115-634-14&P
NAVFAC P-8-647-14&P
T0-35C2-3-445-14
TM-6115-14&P/1
MAINTENANCE OF CONTROL CABLES, 5 FT. AND 25 FT.
4-51. TEST CONTROL CABLE, 5 FT. AND 25 FT.
This task covers: a. Test
INITIAL SETUP
Tools
Equipment Conditions:
Reference
General Mechanics Tool Kit
Para. 4-9 General Instructions.
5180-00-177-7033
Multimeter
6625-10-139-2512
Materials/Parts
Control Cable, 5 ft.
97403-13228E1945-1
Control Cable, 25 ft.
97403-13228E1945-2
TEST
TEST CONTROL CABLE, 5 FT. AND 25 FT.
a.
Use a multimeter and test for
pin-to-pin continuity (O ohms).
Test for open circuit (infinite
ohms) between each pin and pin-
to-connector at both ends of
the cable.
b.
If an open or short occurs
within either cable assembly,
replace the cable.
NOTE
FOLLOW ON MAINTENANCE: Connect
Negative Battery Cable (Para.
4-10).
4-79