Figure 43. External Fuel Line Connection.
Section V. PREVENTIVE MAINTENANCE CHECKS AND SERVICES

Power Plant An/Mjq-18 (Nsn 6115-00-033-1398) (2) Mep-003A 10Kw 60Hz Generator Sets M103A3 2-Wheel, 1-1/2 Ton Modified Trailer Page Navigation
  31    32    33    34    35  36  37    38    39    40    41  
img
. . .
ARMY TM 5-6115-633-14&P
i. Attach power plant to towing vehicle. (Refer to TM 9-2330-213-14&P.)
4-4.  Reinstallation After Movement. After movement to a new worksite, install power plant in
accordance with paragraph 4-2.
Section Ill. REPAIR PARTS, SPECIAL TOOLS, SPECIAL TEST, MEASUREMENT AND
D I A G N O S T I C EQUIPMENT (TMDE)
4-5.  Tools and Equipment. There are no special tools or equipment required to maintain the
AN/MJQ-18 power plant.
4-6.  Maintenance Repair Parts. Repair parts and equipment for maintenance of this power plant are
listed and illustrated in the repair parts and special tools list in Appendix D of this manual.
Section IV. LUBRICATION INSTRUCTIONS
4-7.  General. Detailed instructions for the lubrication of the maior components of the power pIant are
contained in the applicable Lubrication Orders (LO's). Refer to DA Pam 310-1 to ensure that the latest
editions of the L.O.'S are used. This section contains lubrication instructions that are not included in
the Lubrication Orders.
4-8.
Generator Lubrication. Refer to TM 5-6115-585-12.
4.9.
Trailer Assembly Lubrication.
a. Trailer Lubrication. Refer to TM 9-2330-213-14&P for trailer Lubrication Order.
b. Leg Prop Assembly Lubrication. The rear leg prop assembly is a modification to the standard
M103A3 trailer and, as such, does not appear in the associated LO. Semiannually lubricate leg prop
assembly as follows:
WARNING
Clean parts in a well-ventilated area. Avoid inhalation of solvent fumes and
prolonged exposure of skin to cleaning solvent. Wash exposed skin tho-
roughly. Dry cleaning solvent (P-D-680) used to clean parts is potentially
dangerous to personnel and property. Do not use near open flame or
excessive heat. Flash point of solvent is 100F. to 138F. (38C. to 59C.).
(1) Clean hydraulic lubrication fitting and area around lubrication points with P-D-680 or
equivalent.
(2) Inject sufficient GAA grease into hydraulic fitting to lubricate screw theads inside leg prop
assembly.
NOTE
Refer to Lubrication Order in TM 9-2330-213-14&P for lubricating oils
specified for use within different anticipated temperature ranges.
(3) Apply OE lubricating oil to both ends of leg prop assembly pivot shaft.
4-7


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.