Table 3-2. Operator/Crew Preventive Maintenance Checks and Services (PMCS) - Continued
Table 3-2. Operator/Crew Preventive Maintenance Checks and Services (PMCS) - Continued

Power Plant An/Mjq-18 (Nsn 6115-00-033-1398) (2) Mep-003A 10Kw 60Hz Generator Sets M103A3 2-Wheel, 1-1/2 Ton Modified Trailer Page Navigation
  19    20    21    22    23  24  25    26    27    28    29  
img
ARMY TM 5-6115-633-14&P
Table 3-2. Operator/Crew Preventive Maintenance Checks and Services(PMCS) - CONT.
B - Before
D During
A After
W Weekly
M - Monthly
Item to be inspected.
Interval
Procedure: check for and
have repaired, filled, or
Item
Equipment is not
no.
adjusted as needed
ready/available if:
HANDBRAKES CONT
24
BRAKE DRUMS AND HUBS
25
WARNING
A defect in the operation of the
brakes or hub can cause these
parts to get hot enough to cause
serious burns. Use extreme cau-
tion when attempting to detect
heat in this area.
Feel for overheating to detect drag-
Brakes or hub are
ging or binding.
dragging or binding.
REFLECTORS
26
Check for damaged or missing reflectors.
BATTERIES
27
Check battery (37) electrolyte level. Level
should be about 3/4 inch above top of
plates. Add water if level is low. Use
clean water (distilled water if available).